Avantor® ACE® Excel® C18-Amide, HPLC/UHPLC Columns, Analytical, 1,7 µm
: Avantor
Avantor® ACE® Excel® C18-Amide is a uniquely designed stationary phase offering improved retention of polar compounds, enhanced phenolic resolution and alternative selectivity to C18 bonded columns. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1,7 to 5 µm) and complementary phases
- Low bleed for UV and LC/MS compatibility
- C18 hydrophobic plus Amide interactions, compatible with 100% aqueous condition
- Method validation kits contain three different batches of the same phase - available on request
The special design of the Avantor® ACE® C18-Amide ligand incorporates an extended alkyl chain spacer between the silica surface and amide polar group, which gives extra phase stability.
- Catalog No:
- EXL-1712-7502U
- EXL-1712-D1002
- EXL-1712-0302U
- ACE-1P12-GD2U
- EXL-1712-0202U
- EXL-1712-1003U
- EXL-1712-1002U
- EXL-1712-0503U
- EXL-1712-0502U
- Environmentally Preferable:
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Carbon load:
- 16,4%
- 16,4%
- 16,4%
- 16,4%
- 16,4%
- 16,4%
- 16,4%
- 16,4%
- Endcapped:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Max. pressure:
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- 1000 bar
- pH range:
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- 2 - 8
- Surface area:
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- 300 m²/g
- USP code:
- L1
- L1
- L1
- L1
- L1
- L1
- L1
- L1
- Environmental certification:
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- Column FormatPhasePore sizeParticle SizeØ int.Length
- : ACETEXL-1712-0202U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - : ACETEXL-1712-0302U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-1712-0502UAnalyticalC18-Amide100 Å1,7 µm2,10 mm50 mm1 * 1 SZT4 210 zł: ACETEXL-1712-0502U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-1712-7502UAnalyticalC18-Amide100 Å1,7 µm2,10 mm75 mm1 * 1 SZT4 480 zł: ACETEXL-1712-7502U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-1712-1002UAnalyticalC18-Amide100 Å1,7 µm2,10 mm100 mm1 * 1 SZT4 210 zł: ACETEXL-1712-1002U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-1712-D1002AnalyticalC18-Amide (DURSAN (BIO))100 Å1,7 µm2,10 mm100 mm1 * 1 SZT5 170 zł: ACETEXL-1712-D1002
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - EXL-1712-1003UAnalyticalC18-Amide100 Å1,7 µm3,00 mm100 mm1 * 1 SZT4 210 zł: ACETEXL-1712-1003U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - : ACETEXL-1712-0503U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load16,4%EndcappedYesMax. pressure1000 barpH range2 - 8Surface area300 m²/gUSP codeL1Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact
Guard cartridges, ACE UHPLC guard holder may be required
- Column FormatPhasePore sizeParticle SizeØ int.Length
- For analytical UHPLC columns (2.1 - 3.0 mm ID)For analytical UHPLC columns (2.1 - 3.0 mm ID)ACE-1P12-GD2UGuard cartridgeC18-Amide1,7 µm1 * 3 SZT2 290 zł: ACETACE-1P12-GD2U
Low Manufacturing Impact Accessories
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon loadEndcappedMax. pressurepH rangeSurface areaUSP codeEnvironmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact
Guard cartridge holders and accessories
- SeqDescriptionPk
- 10UHPLC guard cartridge holder for 2,1 to 4,6 mm ID columns1: ACETH0011