Avantor® Alltima, HPLC Columns, C8
Supplier: Avantor
Certificates
About this item
Avantor® Alltima HPLC columns are high quality phases designed for general purpose applications.
- Base deactivated silica phases
- Stable bonding for long column lifetime
- Multiple selectivity options
- USP L7
Lower capacity compared to C18 phases. Recommended for reversed phase applications where C18 is too retentive.
Specifications
- Catalog No:
- HICH88372
- 96081/N
- HICH88072
- HICH88073
- HICH88076
- HICH88077
- HICH81392
- HICH81397
- HICH81398
- Environmentally Preferable:
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Low Manufacturing Impact
- Carbon load:
- 9%
- 9%
- 9%
- 9%
- 9%
- 9%
- 9%
- 9%
- Endcapped:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Surface area:
- 340 m²/g
- 340 m²/g
- 340 m²/g
- 340 m²/g
- 340 m²/g
- 340 m²/g
- 340 m²/g
- 340 m²/g
- USP code:
- L7
- L7
- L7
- L7
- L7
- L7
- L7
- L7
- Environmental certification:
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
- ISO 14001:2015 (530840 UM15)
Specifications
Product Information
- Catalog #Column FormatPhaseColumn hardwareParticle SizeØ int.LengthAvailabilityPrice
- ColumnColumnHICH88372AnalyticalC8Stainless steel5 µm2,10 mm150 mmLog in for availability1 * 1 SZT4 940 złSpecifications:
More
Specifications
Environmentally PreferableCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certification - ColumnSpecifications:
Low Manufacturing Impact More
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - ColumnSpecifications:
Low Manufacturing Impact More
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - Column-W (Waters column port)Column-W (Waters column port)HICH81398AnalyticalC8Stainless steel3 µm4,60 mm150 mmLog in for availability1 * 1 SZTSpecifications:
Low Manufacturing Impact More
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - ColumnColumnHICH88072AnalyticalC8Stainless steel5 µm4,60 mm150 mmLog in for availability1 * 1 SZT5 130 złSpecifications:
More
Specifications
Environmentally PreferableCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certification - Column-W (Waters column port)Column-W (Waters column port)HICH88073AnalyticalC8Stainless steel5 µm4,60 mm150 mmLog in for availability1 * 1 SZT5 500 złSpecifications:
Low Manufacturing Impact More
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact - ColumnColumnHICH88076AnalyticalC8Stainless steel5 µm4,60 mm250 mmLog in for availability1 * 1 SZT5 320 złSpecifications:
More
Specifications
Environmentally PreferableCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certification - Column-W (Waters column port)Column-W (Waters column port)HICH88077AnalyticalC8Stainless steel5 µm4,60 mm250 mmLog in for availability1 * 1 SZT5 690 złSpecifications:
Low Manufacturing Impact More
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon load9%EndcappedYesSurface area340 m²/gUSP codeL7Environmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact
Guard Cartridges
Product Information
- Catalog #Column FormatPhaseColumn hardwareParticle SizeØ int.LengthAvailabilityPrice
- All-Guard cartridge for 3,0 – 4,6 mm ID columns (use with holder 80101/N and coupler HI-081)All-Guard cartridge for 3,0 – 4,6 mm ID columns (use with holder 80101/N and coupler HI-081)96081/NGuard cartridgeC8Stainless steel5 µmLog in for availability1 * 3 SZT1 540 złSpecifications:
Low Manufacturing Impact More
Specifications
Environmentally PreferableLow Manufacturing ImpactCarbon loadEndcappedSurface areaUSP codeEnvironmental certificationISO 14001:2015 (530840 UM15)Low Manufacturing Impact