Rurki do pomp Masterflex® L/S® 2-Stop, PharMed® BPT, Avantor®
Supplier: Avantor Fluid Handling
Certificates
About this item
Protect your light-sensitive samples.
- Genuine Masterflex® tubing undergoes robust testing to provide optimal performance / pump life hours with peristaltic pump equipment
- Precision extruded to tight tolerances for high repeatability, accuracy and reproducibility
- Global market leader in range of formulations for most extensive chemical compatibility
- Single-use custom lengths and configurations available to minimise downtime
- Regulatory approvals to match your unique application
- Unique packaging options include packs, cases, and spools for customer-friendly ordering and delivery
Applications: Cell and tissue culture work, pharmaceutical, light-sensitive samples
Characteristics: Nontoxic, nonhemolytic, extremely low permeability, resists acids, bases, and oxidizing agents; heat-sealable, bondable, formable, opaque beige
For use with Masterflex® multichannel pump heads.
For custom tubing lengths and configurations, please contact us. We can provide the tubing type, length, and quantity you need.
- Environmentally Preferable:
Specifications
- Typ:
- 96114-13
- 96114-14
- 96114-15
- 96114-16
- 96114-24
- 96114-25
- 96114-35
- Length per pack:
- 0,38 m (1,25 ft.)
- 0,38 m (1,25 ft.)
- 0,38 m (1,25 ft.)
- 0,38 m (1,25 ft.)
- 0,38 m (1,25 ft.)
- 0,38 m (1,25 ft.)
- 0,38 m (1,25 ft.)
- Maks. ciśnienie:
- 2,7 bar (40 psi)
- 2,7 bar (40 psi)
- 2,7 bar (40 psi)
- 2,7 bar (40 psi)
- 2,7 bar (40 psi)
- 1,4 bar (20 psi)
- 1,05 bar (15 psi)
- Min. temperatura:
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- –51 °C (–60 °F)
- Maks. temperatura:
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- 132 °C (270 °F)
- Min. temperature (dynamic):
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- –20 °C (–4 °F)
- Max. temperature (dynamic):
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- 100 °C (212 °F)
- Maks. odkurzać:
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- 660 mm Hg (26" Hg)
- Pump series:
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- L/S
- Regulatory approvals:
- European Pharmacopoeia;FDA;Non-DEHP;RoHS;USP
- European Pharmacopoeia;FDA;Non-DEHP;RoHS;USP
- European Pharmacopoeia;FDA;Non-DEHP;RoHS;USP
- European Pharmacopoeia;FDA;Non-DEHP;RoHS;USP
- European Pharmacopoeia;FDA;Non-DEHP;RoHS;USP
- European Pharmacopoeia;FDA;Non-DEHP;RoHS;USP
- European Pharmacopoeia;FDA;Non-DEHP;RoHS;USP
- Sterylizacja:
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Autoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 Mrad
- Sterilisation method autoclave:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Sterilisation method EtO:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Sterilisation method gamma:
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Yes
- Suction lift H₂O:
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- 8,8 m (29 ft.)
- Gwarancja:
- Out of box
- Out of box
- Out of box
- Out of box
- Out of box
- Out of box
- Out of box
Specifications
Product Information
- Catalog #OpisRura Ø wew.Materiał rurL/S Masterflex tubing sizeHose barb sizeMaksymalna szybkość przepływuIlośćAvailabilityPrice
- L/S® 2-Stop Precision Pump Tubing, PharMed® BPT, L/S 13; 8/Pk0,80 mm (0,031")PharMed® BPT130,0625"30 ml/min8Log in for availability1 * 8 SZT624 złSpecifications:CE certificate
More
Specifications
Typ96114-13Environmentally PreferableLength per pack0,38 m (1,25 ft.)Maks. ciśnienie2,7 bar (40 psi)Min. temperatura–51 °C (–60 °F)Maks. temperatura132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Maks. odkurzać660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsEuropean Pharmacopoeia;FDA;Non-DEHP;RoHS;USPSterylizacjaAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)GwarancjaOut of boxCE certificate - L/S® 2-Stop Precision Pump Tubing, PharMed® BPT, L/S 14; 8/Pk1,60 mm (0,063")PharMed® BPT140,0625"130 ml/min8Log in for availability1 * 8 SZT624 złSpecifications:
More
Specifications
Typ96114-14Environmentally PreferableLength per pack0,38 m (1,25 ft.)Maks. ciśnienie2,7 bar (40 psi)Min. temperatura–51 °C (–60 °F)Maks. temperatura132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Maks. odkurzać660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsEuropean Pharmacopoeia;FDA;Non-DEHP;RoHS;USPSterylizacjaAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)GwarancjaOut of box - L/S® 2-Stop High-Performance Precision Pump Tubing, PharMed® BPT, L/S 15; 4/Pk4,80 mm (0,189")PharMed® BPT150,1875"1000 ml/min4Log in for availability1 * 4 SZT576 złSpecifications:
More
Specifications
Typ96114-15Environmentally PreferableLength per pack0,38 m (1,25 ft.)Maks. ciśnienie2,7 bar (40 psi)Min. temperatura–51 °C (–60 °F)Maks. temperatura132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Maks. odkurzać660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsEuropean Pharmacopoeia;FDA;Non-DEHP;RoHS;USPSterylizacjaAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)GwarancjaOut of box - L/S® 2-Stop Precision Pump Tubing, PharMed® BPT, L/S 16; 8/Pk3,10 mm (0,122")PharMed® BPT160,125"460 ml/min8Log in for availability1 * 8 SZT624 złSpecifications:
More
Specifications
Typ96114-16Environmentally PreferableLength per pack0,38 m (1,25 ft.)Maks. ciśnienie2,7 bar (40 psi)Min. temperatura–51 °C (–60 °F)Maks. temperatura132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Maks. odkurzać660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsEuropean Pharmacopoeia;FDA;Non-DEHP;RoHS;USPSterylizacjaAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)GwarancjaOut of box - L/S® 2-Stop High-Performance Precision Pump Tubing, PharMed® BPT, L/S 24; 4/Pk6,40 mm (0,252")PharMed® BPT240,25"1800 ml/min4Log in for availability1 * 4 SZT648 złSpecifications:
More
Specifications
Typ96114-24Environmentally PreferableLength per pack0,38 m (1,25 ft.)Maks. ciśnienie2,7 bar (40 psi)Min. temperatura–51 °C (–60 °F)Maks. temperatura132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Maks. odkurzać660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsEuropean Pharmacopoeia;FDA;Non-DEHP;RoHS;USPSterylizacjaAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)GwarancjaOut of box - L/S® 2-Stop Precision Pump Tubing, PharMed® BPT, L/S 25; 8/Pk4,80 mm (0,189")PharMed® BPT250,1875"1000 ml/min8Log in for availability1 * 8 SZT591 złSpecifications:
More
Specifications
Typ96114-25Environmentally PreferableLength per pack0,38 m (1,25 ft.)Maks. ciśnienie1,4 bar (20 psi)Min. temperatura–51 °C (–60 °F)Maks. temperatura132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Maks. odkurzać660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsEuropean Pharmacopoeia;FDA;Non-DEHP;RoHS;USPSterylizacjaAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)GwarancjaOut of box - L/S® 2-Stop High-Performance Precision Pump Tubing, PharMed® BPT, L/S 35; 4/Pk7,90 mm (0,311")PharMed® BPT350,375"2600 ml/min4Log in for availability1 * 4 SZT581 złSpecifications:
More
Specifications
Typ96114-35Environmentally PreferableLength per pack0,38 m (1,25 ft.)Maks. ciśnienie1,05 bar (15 psi)Min. temperatura–51 °C (–60 °F)Maks. temperatura132 °C (270 °F)Min. temperature (dynamic)–20 °C (–4 °F)Max. temperature (dynamic)100 °C (212 °F)Maks. odkurzać660 mm Hg (26" Hg)Pump seriesL/SRegulatory approvalsEuropean Pharmacopoeia;FDA;Non-DEHP;RoHS;USPSterylizacjaAutoclave, Ethylene Oxide, Gamma Irradiation up to 2,5 MradSterilisation method autoclaveYesSterilisation method EtOYesSterilisation method gammaYesSuction lift H₂O8,8 m (29 ft.)GwarancjaOut of box